{"id":4626,"date":"2018-07-24T08:15:40","date_gmt":"2018-07-24T08:15:40","guid":{"rendered":"https:\/\/cablemanagements.com\/cablemanagements\/?page_id=4626"},"modified":"2018-07-24T08:30:33","modified_gmt":"2018-07-24T08:30:33","slug":"technical-help-7-what-additional-information-do-i-need","status":"publish","type":"page","link":"https:\/\/cablemanagements.com\/cablemanagements\/index.php\/technical-help-7-what-additional-information-do-i-need\/","title":{"rendered":"Technical Help->7.\tWhat additional Information do I need&#8230;"},"content":{"rendered":"<div id=\"pl-4626\"  class=\"panel-layout\" ><div id=\"pg-4626-0\"  class=\"panel-grid panel-no-style\" ><div id=\"pgc-4626-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-4626-0-0-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child panel-last-child\" data-index=\"0\" ><div class=\"textwidget\"><p><span style=\"color: #000080;\"><em><strong>What additional Information do I need to supply to the cable tray manufacturer for them to best understand and satisfy my needs?<\/strong><\/em><\/span><\/p>\n<p><strong>Where? Job site and installation considerations<\/strong><\/p>\n<ul>\n<li><span style=\"color: #ff6600;\"><strong>Outdoor<\/strong><\/span>\n<ul style=\"list-style-type: circle;\">\n<li>supports available affect the length and strength requirements<\/li>\n<li>environmental loads, ice, wind, snow, and possibly seismic<\/li>\n<li>corrosion requirements affect the materials and finishes<\/li>\n<li>classified hazardous locations affect the cable types acceptable<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li><span style=\"color: #ff6600;\"><strong>Indoor<\/strong><\/span>\n<ul style=\"list-style-type: circle;\">\n<li>support locations available affect the length and strength of the system<\/li>\n<li>industrial installation may require a 200 lb. Concentrated Load<\/li>\n<li>commercial or institutional installation may make system appearance, system weight, and space available important factors<\/li>\n<li>environmental air handling area may affect cable types, cable tray material, or cable tray type and need for covers<\/li>\n<li>classified hazardous locations affect the cable types acceptable<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>\u00a0<\/p>\n<p><strong>What?<\/strong><\/p>\n<ul>\n<li><span style=\"color: #ff6600;\"><strong><span style=\"font-size: 12pt;\">Type and number of cables to support<\/span><\/strong><\/span>\n<ul style=\"list-style-type: circle;\">\n<li>NEC cable fill requirements dictate size, width and depth, of system<\/li>\n<li>cable support requirement may control bottom type<\/li>\n<li>largest bending radius of cable controls fitting radius<\/li>\n<li>total of cable weight determines load to support<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li><span style=\"color: #ff6600;\"><strong>Future requirements<\/strong><\/span>\n<ul style=\"list-style-type: circle;\">\n<li>cable entry \/ exit freedom<\/li>\n<li>design partially full or an expandable system<\/li>\n<li>support type to allow for needs<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>What additional Information do I need to supply to the cable tray manufacturer for them to best understand and satisfy my needs?Where? Job site and installation considerationsOutdoorsupports available affect the length and strength requirementsenvironmental loads, ice, wind, snow, and possibly seismiccorrosion requirements affect the materials and finishesclassified hazardous locations affect the cable types acceptableIndoorsupport locations &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/cablemanagements.com\/cablemanagements\/index.php\/technical-help-7-what-additional-information-do-i-need\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Technical Help->7.\tWhat additional Information do I need&#8230;&#8221;<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-4626","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/cablemanagements.com\/cablemanagements\/index.php\/wp-json\/wp\/v2\/pages\/4626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cablemanagements.com\/cablemanagements\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cablemanagements.com\/cablemanagements\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cablemanagements.com\/cablemanagements\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/cablemanagements.com\/cablemanagements\/index.php\/wp-json\/wp\/v2\/comments?post=4626"}],"version-history":[{"count":16,"href":"https:\/\/cablemanagements.com\/cablemanagements\/index.php\/wp-json\/wp\/v2\/pages\/4626\/revisions"}],"predecessor-version":[{"id":4632,"href":"https:\/\/cablemanagements.com\/cablemanagements\/index.php\/wp-json\/wp\/v2\/pages\/4626\/revisions\/4632"}],"wp:attachment":[{"href":"https:\/\/cablemanagements.com\/cablemanagements\/index.php\/wp-json\/wp\/v2\/media?parent=4626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}